• NDTC Fire Fighting, Rescue And Security Technology Company Limited

FANERGY

High performance fans

DRIVE WITH ELECTRIC MOTOR

FANERGY with electric motor
Continuous output controller from 0 to 100%

The quite and environmentally friendly alternative

FANERGY high performance fans with electric motors are quiet, environmentally friendly and exhaust-free. They are available in two different sizes with 16" and 21" diameters. The output adjustment is regulated by a continuous controller from 0-100 %.

Universally applicable and flexible in its positioning

The integrated starting current limiter ensures that the drive functions smoothly with a 5 kVA power generator. Both FANERGY models, with E16 and E21 electric motors, can also be connected to any 230 V household socket. This makes them universally applicable and flexible in their positioning. Interior setup is possible without hesitation.


 

Technical data

E16

E21

E16 Ex

Propulsion engine:

230 V / 2.2 kW
Continuously adjustable

400 V / 1.85 kW

Air outlet diameter approx.:

16"/400 mm

21"/530 mm

16"/400 mm

Air flow rate:

14,900 m3/h

31,000 m3/h

14,900 m3/h

Effective air flow rate (injection principle):

> 30,000 m3/h

> 61,000 m3/h

> 30,000 m3/h

Dimensions (W x H x T), in mm:

575 x 635 x 491

695 x 705 x 480

569 x 635 x 488

Weight (filled with oil, empty fuel tank):

approx. 45 kg

approx. 54 kg

approx. 36 kg

Explosion protection:

----

----

Ex II 3G C T3

 

DRIVE WITH COMBUSTION ENGINE

Full power with gasoline engine

The powerful version

FANERGY high performance fans with combustion engines are the most powerful and lightest models.

They are available in three different sizes with 16", 21" and 24" diameters. Equipment with combustion engines are available with Briggs & Stratton or Honda motors.
 

Technical data

V16

V21

V24

Propulsion engine:

B&S 1 cylinder Vanguard 4.8 kW (6.5 hp) or Honda 1 cylinder GX200 4.8 kW (6.5 hp)

Air outlet diameter approx.:

16"/400 mm

21"/530 mm

24"/600 mm

Air flow rate:

23,900 m3/h

35,000 m3/h

36,100 m3/h

Effective air flow rate (injection principle)

> 50,000 m3/h

> 63,500 m3/h

> 65,000 m3/h

Dimensions (W x H x T), in mm:

575 x 635 x 491

695 x 705 x 480

735 x 780 x 495

Weight (filled with oil, empty fuel tank):

approx. 40 kg (B&S)
approx. 37.5 kg (Honda)

approx. 48 kg (B&S)
approx. 45.5 kg Honda

approx. 51 kg (B&S)
approx. 48.5 kg (Honda)


Fuel/tank capacity:


Lead-free gasoline >91 octane/approx. 3.0 l

Running time with one tank of gas:

approx. 110 min at full capacity

POSITIVE PRESSURE VENTILATION

 

Positive pressure ventilation - safer and faster air exchange in case of heat and flue gases

High performance fans serve for the fast, forced ventilation of spaces in residential buildings, halls, etc. in cases of smoke, flue gas and heat generation resulting from fire. For forced ventilation, the high performance fans are placed in the open and fresh air is forced into the building. In doing so, the cone-like air jet seals the intake opening. The introduced air cannot flow back. This light positive pressure sets the air masses in the building in motion in the direction of existing or yet to be created openings, such as windows, smoke flaps, etc. The resulting airflow carries heat and flue gases outside into the ambient air without great turbulence.

The positive pressure ventilation works independent of the size of the building. The mode of action can be reinforced with multiple coolings fans, e.g. in case of a highrise fire or large hall fire. Thus, nearby areas also remain smoke and gas-free. 

The advantages of positive pressure ventilation:

  • Quick improvement of visibility
  • Fresh air in evacuation areas
  • Quick lowering of the ambient temperature
  • Immediate dissipation of water vapor
  • Even smoke extraction of the floor and ceiling areas as well as corners
  • Airflow control possible

INTEGRATED WATER VAPOR CARTRIDGE

Integrated FANERGY water vapor cartridge
With foam compound during an operation

The sophisticated concept of the FANERGY high performance fan is versatile in application. An integrated water vapor cartridge is optionally available for all models and sizes. Light and space-saving, it can be used to support extinguishing tasks, as object protection or as a light foam generator.

  • Permanently integrated water vapor cartridge, made of stainless steel with Storz-C coupling - therefore, the hose line can be connected immediately
  • Lightening fast, easy to connect and operational ready
  • Flow rate at 7 bar approx. 200 l
  • Working pressure is approx. 6 - 10 bar

Only a foam net, and potentially an air tube and a Z2 proportioner, is required to use it as a light foam generator.

STRONG CONCEPT. TECHNICAL FINESSE.

Incremental nozzle adjustment 
Easy to set up and transport 
Compact design

Nozzle position swivels continuously

  • Generous adjustable range of -8° to + 20°
  • A maintenance-free gas strut is used for comfortable, easy and continuous adjustment.
  • Easy and practical tilt adjustment
  • This enables an optimal ventilation without additional accessories or measures, even in difficult conditions, such as e.g., high- or low-lying supply air openings

Light handling. Lighting fast set up.

  • Open socket - the large and smooth-running wheels (for 21"/24" models) automatically swivel out
  • Extremely compact dimensions and the smallest transport dimensions (fastening in vehicles)
  • Can be easily and ergonomically transported to the scene like a trolley case

Extremely compact design

With retracted handle, the light and compact FANERGY requires very little space in the vehicle.

Low-noise fan impeller

The low-noise fan impeller, in connection with the direct drive, delivers extremely powerful airflow and is very quiet in the process.

STANDARD EQUIPMENT, ACCESSORIES, MAINTENANCE

Adapter for exhaust hose 
Door wedges

Standard equipment

  • Water vapor cartridge, standard or retrofit
  • Adapter for exhaust hose for Briggs & Stratton and Honda motor
  • Two door wedges

Accessories

  • Water vapor cartridge integrates for 16", 21" and 24" cooling fans with Storz C-coupling
  • Foam net for 16", 21" and 24" cooling fans
  • Z2 proportioner with Storz C couplings
  • Suction hose 25 mm/1.5 m for proportioner
  • Discharge hose, synthetic special 5 m with Storz C couplings
  • PAE air tube for 16", 21" and 24" cooling fans
  • Stable air tube for 16", 21" and 24" cooling fans
  • Air guide hood for 16", 21" and 24" cooling fans
  • Exhaust gas hose
  • Service hour meter for cooling fans with combustion engines

Maintenance-free components

  • Gas strut
  • Electric motor

A clear view in critical moments

Ventilation of burning structures with high performance fans is among the most critical practices in modern firefighting. High performance fans of the FANERGY series quickly provide clear visibility for emergency personnel, lower temperatures and remove smoke from escape routes. As a result, less time is needed for searching and extinguishing, victims are rescued faster and risks for fire fighters and rescue forces are minimized. Whether used as positive pressure fan or for other tactical applications, Rosenbauer FANERGY high performance fans are ideal in all respects. Depending on the application and employed tactics, they my also be used with water or as a light foam generator.

Impresses with

  • Features tested in practice
  • High air flow rate
  • Large swivel range
  • Light handling
  • Quickly ready for operation

Other product